PA / Nylon vs Polycarbonate / PC: Which Filament Should You Use?
Nylon prioritises tough, wear-capable parts while PC raises heat resistance and printer demands.
Choose PA / Nylon when
- You need toughness and can control moisture.
Choose Polycarbonate / PC when
- High heat resistance is the deciding factor.
Requirements that decide this pair
| Requirement | PA / Nylon | Polycarbonate / PC |
|---|---|---|
| Service requirement | Investigate a grade when wear and toughness motivate the choice. | Investigate a grade when loaded thermal service is the deciding requirement. |
| Dimensional evidence | Define moisture conditioning before accepting measured fit. | Define the blend, thermal process and cooled measurement state. |
| Available printer | Verify drying, feed path and any abrasive reinforcement requirements. | Verify the exact documented nozzle, bed and enclosure environment; hotend temperature alone is insufficient. |
An engineering cover needs a grade-level qualification
A hypothetical 90 mm protective cover may require toughness, heat stability and accurate mounts. Nylon and PC are candidate families; compare exact datasheets at the operating temperature, moisture state and load. Print a dimensional coupon and final mounting geometry before choosing. Neither a family label nor a coupon certifies the assembled cover.
Hypothetical application, not an InspectMesh physical material test.
When the initial choice changes
A moisture-sensitive fit may change the nylon shortlist. A printer unable to hold the documented PC environment can remove PC from consideration even if its datasheet looks attractive. Blends and reinforced grades can reverse broad comparisons.
Evidence that would change this choice
Conditional choice: Choose between documented exact formulations and available hardware, rather than two engineering-family labels.
The examples are unfilled PA11 and PC Blend. Their printed specimens use different printers, thermal settings and slicers; mechanical conditioning is not specified. Read their separate values without a numerical winner.
Next evidence to collect: For the 90 mm engineering cover, keep moisture-conditioned mounting fit, thermal method/load and print capability as three decisions. Verify PA11 chamber capability and PC Blend surface/profile requirements. Its 93 °C at 1.80 MPa and 113 °C at 0.45 MPa are separate historical tests; unmatched PA11/PC data remain separate.
Interpret the two PC Blend test loads
Family context explains the trade-off above. The named examples below retain their own formulation and test scope.
Published product examples, separate from the family view
These are identified formulations chosen to show how to read evidence. Selecting a family does not select a brand for your part. HDT rows are grouped by reported test load, never by the highest temperature. An absent matching-load result remains unavailable; matching a load alone does not establish matching specimen or conditioning.
Prusament PA11 evidence · Prusament PC Blend evidence
| Property | Prusament PA11 | Prusament PC Blend | Comparison scope |
|---|---|---|---|
| Density | 1.02 g/cm³ Prusa Polymers, v1.0Source conditionsMethod: ISO 1183; load: not specified; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified. p. 2, typical properties. Checked 2026-10-29. | 1.22 g/cm³ Prusa Polymers, v1.1Source conditionsMethod: Prusa Polymers; load: not specified; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified. p. 2, typical properties. Checked 2026-11-03. | Separate published values Different or unspecified method, specimen, conditioning, test temperature. Read each source separately; these values do not establish which material performs better in your part. |
| Heat deflection temperature (1.80 MPa) | Not found in this example; not zero. | 93 °C Prusa Polymers, v1.1Source conditionsMethod: ISO 75; load: 1.80 MPa; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified. p. 2, typical properties. Checked 2026-11-03. | Unavailable A numeric result is not published for one or both selected examples. Missing is not zero. |
| Heat deflection temperature (0.45 MPa) | Not found in this example; not zero. | 113 °C Prusa Polymers, v1.1Source conditionsMethod: ISO 75; load: 0.45 MPa; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified. p. 2, typical properties. Checked 2026-11-03. | Unavailable A numeric result is not published for one or both selected examples. Missing is not zero. |
| Tensile modulus | 1.2 ± 0 GPa Prusa Polymers, v1.0Source conditionsMethod: ISO 527-1; load: not specified; specimen: CORE One+ firmware 6.4.0; 0.4 mm High-Flow CHT; PrusaSlicer 2.9.6; 0.20 mm layers; 100% rectilinear; 2 perimeters; no top/bottom; 275 °C nozzle; 100 °C bed; 55 °C chamber; orientation: Horizontal; conditioning: not specified; test temperature: not specified. p. 2, printed-specimen table; p. 3, footnote setup. Checked 2026-10-29. | 1.9 ± 0.1 GPa Prusa Polymers, v1.1Source conditionsMethod: ISO 527-1; load: not specified; specimen: MK3S; PrusaSlicer 2.1.1; 0.20 mm FAST; 100% rectilinear infill; 2 perimeters; no top/bottom; 275 °C nozzle; 115 °C bed; orientation: Horizontal; conditioning: not specified; test temperature: not specified. p. 2, printed-specimen table; p. 3, footnote setup. Checked 2026-11-03. | Separate published values Different or unspecified specimen, conditioning, test temperature. Read each source separately; these values do not establish which material performs better in your part. |
HDT is a loaded deflection test, not a continuous service limit. Modulus measures stiffness; it is not impact strength. Shore A and D remain different scales.
Open this pair in the comparison tool
Prepare the exact formulation
Both need product-specific thermal, surface and drying preparation. Verify printer material documentation and remeasure cooled/conditioned dimensions; do not infer support from a 300 C hotend alone.
Use the spool maker's settings and datasheet; a family-wide nozzle range is not a qualified profile.
Sources for this decision
- Prusa Research: PA-NYLON material guidance (checked 2026-10-09)
- Prusa Research: PC material guidance (checked 2026-10-09)
Sources describe the material families and printing preparation. Application dimensions and qualification steps above are illustrative design decisions.
PA / Nylon guide · Polycarbonate / PC guide · Use the selector
Reviewed 2026-11-03.