InspectMesh
Tools

Planning & calibration

3D Printer Fit Checker3D PrintersCompare 3D Printers3D Print Cost Calculator3D Printing Price CalculatorFilament Length CalculatorFlow Rate CalculatorTolerance & ClearanceShrinkage CalculatorOrientation PlannerBed Layout Planner

After slicing

G-code Viewer & Preflight
View all 3D tools
STL toolsSTL ViewerSTL Quality CheckerSTL Print Preflight CheckerSTL Repair ToolSTL Watertight CheckerSTL Manifold CheckerSTL Dimensions CheckerSTL Scale ToolSTL Wall Thickness CheckerSTL Overhang CheckerSTL SplitterSTL Volume CalculatorSTL Triangle CounterSTL File Size ReducerSTL to 3MF Converter
3MF tools3MF Viewer3MF Quality Checker3MF Print Preflight Checker3MF Repair Tool3MF Watertight Checker3MF Manifold Checker3MF Dimensions Checker3MF Wall Thickness Checker3MF Overhang Checker3MF Volume Calculator3MF Triangle Counter3MF to STL Converter
MaterialsGuidesExamplesContact
Home›Compare 3D Printing Materials›PETG vs TPU

PETG vs TPU: Which Filament Should You Use?

PETG suits semi-rigid functional parts, while TPU trades rigidity for elasticity.

Choose PETG when

  • You need a firm functional shell.

Choose TPU when

  • You need a compliant or protective part.

Requirements that decide this pair

RequirementPETGTPU
Firm outer housingA candidate for a firmer shell and stable locating surfaces.A flexible case can allow movement; define the permitted displacement.
Cushioning insertA thin part can flex, but that does not establish controlled compression.Investigate a hardness-specific insert under the real load and recovery requirement.
One piece or assemblyCan pair with a separately made compliant insert.An integrated flexible case changes insertion, support-removal and alignment requirements.

Separate a firm housing from the compressible insert

A hypothetical 70 mm housing holds a removable 2 mm cushioning insert. PETG is a candidate for the firm shell, while TPU is a candidate for the insert. Check insertion clearance in the shell and compression/rebound of the insert at the actual load. The dimensions are design inputs, not measured fit tolerances.

Hypothetical application, not an InspectMesh physical material test.

When the initial choice changes

A single-piece flexible case can favour TPU when alignment is not critical. A tight locating surface can favour the firmer design; thin PETG geometry may flex too, so evaluate shape as well as polymer.

Evidence that would change this choice

Conditional choice: Investigate PETG when bending is an unwanted defect; investigate TPU when controlled deformation is the function.

A toughness description does not say whether the part should bend. The named TPU sheet reports hardness and loaded deflection; neither property establishes impact protection for the intended insert.

Next evidence to collect: For the removable 2 mm insert, separate the target compliance from sustained compression and force retention. Record whether load or deformation is held, actual temperature, elapsed time and recovery readings. A Shore number supplies neither whole-part force nor compression-set performance.

Choose the right time-dependent observation

Family context explains the trade-off above. The named examples below retain their own formulation and test scope.

Published product examples, separate from the family view

These are identified formulations chosen to show how to read evidence. Selecting a family does not select a brand for your part. HDT rows are grouped by reported test load, never by the highest temperature. An absent matching-load result remains unavailable; matching a load alone does not establish matching specimen or conditioning.

Prusament PETG evidence · Prusament TPU 95A evidence

Compare reported properties and conditions, without an overall winner
Property Prusament PETG Prusament TPU 95A Comparison scope
Density

1.27 g/cm³

Prusa Polymers, v1.1
Source conditions

Method: ISO 1183; load: not specified; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified.

p. 2, typical properties. Checked 2026-10-29.

1.25 g/cm³

Prusa Polymers, v1.0
Source conditions

Method: ISO 1183; load: not specified; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified.

p. 2, typical properties. Checked 2026-10-29.

Separate published values

Different or unspecified specimen, conditioning, test temperature. Read each source separately; these values do not establish which material performs better in your part.

Heat deflection temperature (1.80 MPa)

68 °C

Prusa Polymers, v1.1
Source conditions

Method: ISO 75; load: 1.80 MPa; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified.

p. 2, typical properties. Checked 2026-10-29.

78.6 °C

Prusa Polymers, v1.0
Source conditions

Method: ISO 75; load: 1.80 MPa; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified.

p. 2, typical properties. Checked 2026-10-29.

Separate published values

Different or unspecified specimen, orientation, conditioning, test temperature. Read each source separately; these values do not establish which material performs better in your part.

Tensile modulus

1.5 ± 0.1 GPa

Prusa Polymers, v1.1
Source conditions

Method: ISO 527-1; load: not specified; specimen: MK3; Slic3r Prusa Edition 1.40.0; 0.20 mm FAST; 100% rectilinear infill; 2 perimeters; no top/bottom; 250 °C nozzle; 80 °C bed; orientation: Horizontal; conditioning: not specified; test temperature: not specified.

p. 2, printed-specimen table; p. 3, footnote setup. Checked 2026-10-29.

Not found in this example; not zero. Unavailable

A numeric result is not published for one or both selected examples. Missing is not zero.

Shore A hardness Not found in this example; not zero.

92 ± 0.4 Shore A

Prusa Polymers, v1.0
Source conditions

Method: Prusa Polymers; load: not specified; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified.

p. 2, typical properties. Checked 2026-10-29.

Unavailable

A numeric result is not published for one or both selected examples. Missing is not zero.

Shore D hardness Not found in this example; not zero.

39 ± 0.7 Shore D

Prusa Polymers, v1.0
Source conditions

Method: Prusa Polymers; load: not specified; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified.

p. 2, typical properties. Checked 2026-10-29.

Unavailable

A numeric result is not published for one or both selected examples. Missing is not zero.

HDT is a loaded deflection test, not a continuous service limit. Modulus measures stiffness; it is not impact strength. Shore A and D remain different scales.

Open this pair in the comparison tool

Prepare the exact formulation

PETG supports and bed adhesion need a tuned profile. TPU requires hardness-specific feed and support preparation; difficult support removal can make a different part orientation or split design preferable.

Use the spool maker's settings and datasheet; a family-wide nozzle range is not a qualified profile.

Sources for this decision

  • Prusa Research: PETG material guidance (checked 2026-10-09)
  • Prusa Research: TPU material guidance (checked 2026-10-09)

Sources describe the material families and printing preparation. Application dimensions and qualification steps above are illustrative design decisions.

PETG guide · TPU guide · Use the selector

Reviewed 2026-11-03.

Get occasional updates on new tools and practical 3D-print guides.

Verification (required)

Enter your email to start verification.

Simple, browser-friendly tools for better 3D prints.

ExamplesPrivacyCookiesContact