Polypropylene / PP vs PETG: Which Filament Should You Use?
PP is specialised for lightweight, flexible and chemically resistant uses; PETG is usually the more broadly approachable choice.
Choose Polypropylene / PP when
- You need PP-specific chemical resistance or living-hinge behaviour.
Choose PETG when
- You need a general functional filament with easier adhesion.
Requirements that decide this pair
| Requirement | Polypropylene / PP | PETG |
|---|---|---|
| Integral hinge | A candidate to investigate for repeated flex; specify radius, orientation and cycles. | A separate mechanical hinge may fit a firmer enclosure design better. |
| Rigid box | Low density does not establish enough stiffness for the designed wall. | A candidate when a firmer general-purpose shell is the main need. |
| Bed preparation | Confirm a PP-compatible surface and warp-control procedure. | Use the exact PETG surface and separation routine instead of transferring the PP setup. |
A hinged lid and a rigid box should not share one selection rule
For a hypothetical 1 mm hinge strip on a 60 mm lid, PP is a candidate when repeated flexing is the design goal. PETG is the candidate for a firmer general-purpose box. Specify the bend radius and required cycles, then test the exact printed orientation. The 1 mm input is not a proven living-hinge specification.
Hypothetical application, not an InspectMesh physical material test.
When the initial choice changes
A lid that does not need an integral hinge may favour PETG and a mechanical joint. Chemical contact can override either choice: obtain data for the chemical, concentration, temperature and exposure duration. No blanket resistance certification follows from choosing PP.
Evidence that would change this choice
Conditional choice: Investigate a specific PP grade for the mass or attachment brief; keep PETG when its established functional workflow already works.
The PP example is carbon-filled, with density 0.91 g/cm³ versus the named PETG 1.27. Equal-volume arithmetic is not a sliced-weight comparison, and a filled PP example cannot establish unfilled hinge life.
Next evidence to collect: For a hinged lid, record repeated bend cycles separately from the force retained by a clip held deflected. Obtain exact unfilled-hinge-grade evidence when that is the design; the named PP Carbon Fiber density and hardware instructions do not establish unfilled hinge life or creep. Confirm adhesion before changing the joint.
Separate cycling from sustained deflection
Family context explains the trade-off above. The named examples below retain their own formulation and test scope.
Published product examples, separate from the family view
These are identified formulations chosen to show how to read evidence. Selecting a family does not select a brand for your part. HDT rows are grouped by reported test load, never by the highest temperature. An absent matching-load result remains unavailable; matching a load alone does not establish matching specimen or conditioning.
Prusament PP Carbon Fiber evidence · Prusament PETG evidence
| Property | Prusament PP Carbon Fiber | Prusament PETG | Comparison scope |
|---|---|---|---|
| Density | 0.91 g/cm³ Prusa Polymers, v1.0Source conditionsMethod: ISO 1183; load: not specified; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified. p. 2, typical properties. Checked 2026-10-29. | 1.27 g/cm³ Prusa Polymers, v1.1Source conditionsMethod: ISO 1183; load: not specified; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified. p. 2, typical properties. Checked 2026-10-29. | Separate published values Different or unspecified specimen, conditioning, test temperature. Read each source separately; these values do not establish which material performs better in your part. |
| Heat deflection temperature (1.80 MPa) | Not found in this example; not zero. | 68 °C Prusa Polymers, v1.1Source conditionsMethod: ISO 75; load: 1.80 MPa; specimen: not specified; orientation: not specified; conditioning: not specified; test temperature: not specified. p. 2, typical properties. Checked 2026-10-29. | Unavailable A numeric result is not published for one or both selected examples. Missing is not zero. |
| Tensile modulus | Not found in this example; not zero. | 1.5 ± 0.1 GPa Prusa Polymers, v1.1Source conditionsMethod: ISO 527-1; load: not specified; specimen: MK3; Slic3r Prusa Edition 1.40.0; 0.20 mm FAST; 100% rectilinear infill; 2 perimeters; no top/bottom; 250 °C nozzle; 80 °C bed; orientation: Horizontal; conditioning: not specified; test temperature: not specified. p. 2, printed-specimen table; p. 3, footnote setup. Checked 2026-10-29. | Unavailable A numeric result is not published for one or both selected examples. Missing is not zero. |
HDT is a loaded deflection test, not a continuous service limit. Modulus measures stiffness; it is not impact strength. Shore A and D remain different scales.
Open this pair in the comparison tool
Prepare the exact formulation
Prusa documents poor PP adhesion on standard PEI and recommends a suitable PP surface. Check warp control and the exact spool profile; use a PETG-specific surface/separation routine for the alternative.
Use the spool maker's settings and datasheet; a family-wide nozzle range is not a qualified profile.
Sources for this decision
- Prusa Research: PETG material guidance (checked 2026-10-09)
- Prusa Research: PP material guidance (checked 2026-10-09)
Sources describe the material families and printing preparation. Application dimensions and qualification steps above are illustrative design decisions.
Polypropylene / PP guide · PETG guide · Use the selector